Sampling Port Requirements for Isokinetic Sampling in Stack Emission Test

Sampling Port Requirements for Isokinetic Sampling 

The details of sampling port requirements for stack/ duct / chimney "Isokinetic Sampling" as per the US EPA Method 01-05 are as follows:
 Required each stack two (02) sampling ports at 90˚ apart, if the stack diameter is less than < 3.1 meters including port length, or four (04) sampling ports required, if the stack diameter is > 3.1 meters included the port length. Each port as consist a 4 Inches inside diameter (ID) opening fitted with a bolted blind flange installed as a cover. Locate all sampling ports at least eight (08) stack/ duck / chimney downstream and two (02) diameters downstream from any flow disturbance such as bend, expansion, contractions, or visible flame. Orientation of sampling location illustrated in below figure as

Sampling Port Requirements for Isokinetic Sampling in Stack Emission Test